Settling Time (of an Oscillator)
 
The time (tST) required for the output frequency of an oscillator to enter and stay within a specified error band (+fST) centered around a reference frequency (fr) after application of a step input voltage (for a VCO) or current (for a YTO). A reference time (tr) shall be specified for determining the reference frequency (fr). The period of measurement ends at the reference time (tr).